Dry-Type Transformers background

Dry-Type Transformers

Cast Resin Dry-Type Transformers (100 kVA – 15 MVA)

Product Overview

Our cast resin dry-type transformers are the premier choice for indoor substations, urban skyscrapers, and environmentally sensitive projects. Because they contain no flammable oils or fluids, they eliminate fire hazards, require no containment dikes, and are virtually maintenance-free. Fully compliant with IEC 60076-11, these transformers are commonly installed in hospitals, schools, high-rise office towers, shopping malls, underground transit systems, and marine vessels.

Dry-Type Transformers

Key Advantages

Fire Safety (Self-Extinguishing)

Encapsulated in high-grade epoxy cast resin, the windings will not ignite or feed a fire, releasing no toxic fumes.

Zero Environmental Risk

Without liquid coolant, there is no threat of oil leakage or soil and groundwater contamination.

Maintenance-Free Operation

Eliminates regular oil purification, dielectric testing, degassing, and gasket monitoring cycles.

Compact Installation footprint

A smaller space envelope allows direct placement inside utility rooms close to loads, lowering low-voltage cable costs.

Core Parameters

Rating Capacity

100 kVA - 15 MVA

Voltage Level

Up to 36 kV

Standards Compliance

IEC 60076-11 / E2-C2-F1

Common Applications

  • Hospitals, Medical Centers, & Educational Institutions
  • High-rise Residential & Commercial Office Towers
  • Subway Stations, Airports, & Railway Infrastructures
  • Marine Ships, Offshore Oil Rigs, & Vessels
  • Solar & Wind Power Substations in Eco-sensitive zones

Technical Specification Data

Technical ParameterStandard Range / Option
Power Ratings100 kVA to 15 MVA (custom ratings on request)
HV Voltage Level6 kV, 11 kV, 15 kV, 20 kV, 22 kV, 33 kV, 36 kV
LV Voltage Level400 V, 415 V, 420 V, 690 V (custom LV configurations supported)
Frequency50 Hz (60 Hz available on request)
Cooling MethodAN (Air Natural) / AF (Air Forced - increases output up to 40%)
Insulation ClassClass F (155°C temperature limit) / Class H (180°C temperature limit)
Enclosure ProtectionIP00 (without enclosure), IP20, IP21, IP23, IP31, IP44 (indoor/outdoor sheets)
Partial DischargeGuaranteed less than 10 pC at 1.3 Um (highly reliable core bonding)
Climatic & Fire ClassE2 (climatic), C2 (thermal shock resistance), F1 (fire performance)
Winding TypeHV vacuum cast resin coils / LV vacuum impregnated or cast coils

Standard & Optional Accessories

PT100 Temperature Sensors (embedded in LV windings, 3 or 4-wire configuration)
Digital Temperature Controller unit with alarm & trip contact microswitches
Cross-flow cooling fans (axial type) to boost continuous power rating by 30-40%
Flexible copper connectors (shunt braids) for busbar terminals
Anti-vibration pads (elastomeric damping pads) to limit structure-borne acoustic noise
Bi-directional rollers / wheels for placement adjustments
Grounding/Earthing copper terminals on frame
Door limit safety switch contacts for IP enclosures
Space heaters to prevent condensing in humid stand-by conditions

Testing & Quality Assurance

Our cast resin dry-type transformers are verified through comprehensive routine tests according to IEC 60076-11. We guarantee partial discharge levels below 10 pC, verifying the zero presence of voids in the cast resin. Standard checks include: Winding Resistance, Voltage Ratio and Vector Group verification, Impedance Voltage & Load Loss, No-Load Loss and Current, Applied & Induced AC Overvoltage tests, and Partial Discharge measurement.

Compliance Standard

ISO 9001 & IEC 60076 Verified

Need a high-safety dry-type transformer?

Get in touch with our engineers. We provide compact, fire-safe cast resin solutions tailored to your building, marine, or industrial substation.

Message Us